For 100Gb/s QSFP28 links, use a passive copper DAC up to 5 m, an active optical cable (AOC) from 5 m up to 100 m, and transceivers with fiber when the run is longer or passes through patch panels. Use a QSFP28-to-4xSFP28 breakout DAC when one 100GbE switch port must feed four 25GbE servers. This guide is for engineers choosing cables for InfiniBand EDR or 100GbE Ethernet gear.

The four options at a glance

All four options plug into an SFF-8665 QSFP28 port on the 100G side and carry four lanes of up to 25Gb/s. They differ in medium, reach and power.

  • Passive copper DAC (MCP1600 series): four copper pairs and no active electronics in the signal path. NVIDIA lists 0.1 W maximum power. Lengths run from 0.5 m to 5 m.
  • Active optical cable (MFA1A00 series): four VCSEL-based multimode fiber transceivers per end, with the fiber permanently attached. Power is 2.2 W typical per end with retiming. Lengths run up to 100 m. NVIDIA specifies BER better than 1E-15.
  • Breakout DAC (MCP7F00-A series): one QSFP28 end splits into four SFP28 ends, 100GbE to 4x25GbE, up to 5 m. This is an Ethernet part.
  • Transceivers plus fiber: MMA1B00 SR4 modules use an MPO connector and reach 70 m on OM3 or 100 m on OM4. The MMA1L10-CR LR4 module uses duplex LC on single-mode fiber and reaches up to 10 km.

Decision table by distance

Short copper cables loop between two rack switches while longer cables run up to an overhead tray
Reach of 100G QSFP28 cable typesLog-scale ruler from 0.5 m to 10 km. MCP1600 DAC and MCP7F00 breakout reach up to 5 m, MFA1A00 AOC 3 m to 100 m, MMA1B00 SR4 70 m on OM3 and 100 m on OM4, MMA1L10-CR LR4 up to 10 km.same rackadjacent rackrowdata hallbetween roomsMCP1600 DACup to 5 mMCP7F00 breakoutup to 5 mMFA1A00 AOC3 m to 100 mMMA1B00 SR470 m OM3 · 100 m OM4MMA1L10-CR LR4up to 10 km0.5 m1 m2 m5 m10 m30 m100 m1 km10 kmReach of 100G QSFP28 cable typesLog-scale ruler from 0.5 m to 10 km. MCP1600 DAC and MCP7F00 breakout reach up to 5 m, MFA1A00 AOC 3 m to 100 m, MMA1B00 SR4 70 m on OM3 and 100 m on OM4, MMA1L10-CR LR4 up to 10 km.same rackadjacent rackrowdata hallbetween roomsMCP1600 DACup to 5 mMCP7F00 breakoutup to 5 mMFA1A00 AOC3 m to 100 mMMA1B00 SR470 m OM3 · 100 m OM4MMA1L10-CR LR4up to 10 km0.5 m2 m5 m10 m100 m10 km
Maximum reach by cable type, from the decision table (log scale).
DistanceTypical linkFirst choiceAlternativeNotes
Up to 2 m (same rack)Server or GPU node to top-of-rack switchMCP1600 DACMCP7F00 breakout to 25GbE serversEthernet DACs up to 2 m are specified as CA-25G-N, no FEC
2.5 m to 5 m (adjacent rack)Rack to rack, short switch-to-switchMCP1600 DAC (26 AWG at most of these lengths)MFA1A00 AOC, 3 m or 5 mEthernet DACs of 3 m to 5 m are specified as CA-25G-L with RS-FEC
5 m to 30 m (row)End-of-row, leaf to spine in one rowMFA1A00 AOCSR4 transceivers and MPO fiberNo MCP1600 DAC is offered beyond 5 m
30 m to 100 m (data hall)Across the roomMFA1A00 AOC, 50 m or 100 mMMA1B00 SR4 on OM4 (100 m) or OM3 (70 m)Choose transceivers if the fiber passes through patch panels
Over 100 mBetween rooms or buildingsMMA1L10-CR LR4None in this familySingle-mode, duplex LC, up to 10 km

How to choose between DAC, AOC and transceivers

Power per cable end: DAC vs AOCMCP1600 passive DAC: 0.1 W maximum. MFA1A00 AOC: 2.2 W typical per end with retiming, 1.5 W without retiming, about 4.4 W per link.MCP1600 DAC (maximum)MFA1A00 AOC (typical)Per end0.1 W2.2 WAOC: 2.2 W per end with retiming, 1.5 W without, so about 4.4 W per link.Power per cable end: DAC vs AOCMCP1600 passive DAC: 0.1 W maximum. MFA1A00 AOC: 2.2 W typical per end with retiming, 1.5 W without retiming, about 4.4 W per link.MCP1600 DAC (maximum)MFA1A00 AOC (typical)Per end0.1 W2.2 WAOC: 2.2 W per end with retiming, 1.5 W without, soabout 4.4 W per link.
A passive DAC draws almost nothing; an AOC has powered optics in each end.

Power and cost

A DAC draws almost nothing: 0.1 W maximum. An MFA1A00 AOC draws 2.2 W typical at each end with retiming, so about 4.4 W per link. NVIDIA positions the MCP1600 as a cost-effective alternative to fiber optics. If the run fits in 5 m, copper is the default.

Bulk, bend radius and airflow

Copper gets thicker as it gets longer. The MCP1600-E uses 30 AWG up to 2 m and 26 AWG from 2.5 m to 5 m. Even the thinnest 0.5 m, 30 AWG MCP1600-C has a minimum bend radius of 35.5 mm for a single bend and 71 mm for repeated bends. Thick copper bundles at the rear of a rack can restrict airflow. NVIDIA states that AOCs enable increased airflow, tighter bend radii and much longer reach than DAC cables.

Fixed length or flexible fiber

An AOC is one fixed-length assembly. If one end fails, you replace the whole cable. Transceivers let you reuse installed fiber, patch through panels and change lengths without changing optics. For a point-to-point run of known length, the AOC is simpler. For structured cabling, use transceivers.

The C and E letters: Ethernet vs InfiniBand EDR

Reading an MFA1A00 part numberMFA1A00-E010: MFA1A00 is the 100Gb/s QSFP28 AOC series; E means InfiniBand EDR and C means 100GbE Ethernet; 010 is the length, 10 m. MFA1A00-E100 is the 100 m version.MFA1A00-E0101231MFA1A00AOC series100Gb/s QSFP28 active optical cable3010Length010 is 10 m; MFA1A00-E100 is 100 m2EFabricE = InfiniBand EDR, C = 100GbE Ethernet. MCP1600DACs use the same letters.Reading an MFA1A00 part numberMFA1A00-E010: MFA1A00 is the 100Gb/s QSFP28 AOC series; E means InfiniBand EDR and C means 100GbE Ethernet; 010 is the length, 10 m. MFA1A00-E100 is the 100 m version.MFA1A00-E0101231MFA1A00AOC series100Gb/s QSFP28 active optical cable2EFabricE = InfiniBand EDR, C = 100GbE Ethernet. MCP1600DACs use the same letters.3010Length010 is 10 m; MFA1A00-E100 is 100 m
Buy the letter that matches your fabric: E for InfiniBand EDR, C for 100GbE.

In NVIDIA's ordering tables, MCP1600-C and MFA1A00-C parts are listed for 100GbE Ethernet. MCP1600-E and MFA1A00-E parts are listed for 100Gb/s InfiniBand EDR. The MCP7F00-A breakout is a 100GbE to 4x25GbE Ethernet part.

The rule is not symmetric for optics. NVIDIA states that EDR AOCs and transceivers, including MMA1B00-E100, work in NVIDIA end-to-end Ethernet applications. The Ethernet transceiver MMA1B00-C100D is generally not supported in InfiniBand applications. For DACs, NVIDIA's specs list the MCP1600-E only for InfiniBand EDR and the MCP1600-C only for Ethernet. Buy the letter that matches your fabric.

What it does NOT work with

  • HDR and NDR speeds. These QSFP28 parts are rated up to 100Gb/s. They will not carry HDR or NDR link rates. Use cables rated for that generation.
  • 100Gb/s in QSFP+ 40GbE ports. The port sets the ceiling. A QSFP28 cable in a 40GbE QSFP+ port cannot run at 100Gb/s. Some parts list 40G modes (MCP7F00: 40GbE to 4x10GbE; MMA1B00-C100D: 40GBASE-SR4). Check the spec of the exact part.
  • Ethernet-only parts in an InfiniBand fabric. Do not plan MMA1B00-C100D, MCP1600-C or MCP7F00-A parts into an EDR fabric.
  • A breakout on a port that is not split. The switch port must be configured for split mode. On the SN2100, each port can split into 4xSFP28 or 2xQSFP28 with no blocking. On the SN2700 and SN2410, only the top ports split into four SFP28 ports, and the bottom port below is blocked. In Onyx, set the port to split-4. In Cumulus Linux, edit /etc/cumulus/ports.conf.
  • FEC off on 3 m to 5 m Ethernet DACs. These lengths are specified as CA-25G-L with RS-FEC. Keep RS-FEC enabled on both ends.
  • Treating an AOC as copper. An AOC has optics in each end and draws power. It is not a passive DAC and cannot be cut or field-terminated.

Sources: NVIDIA MCP1600-C DAC product brief (PDF); MCP1600-C specifications; MCP1600-E ordering list; MFA1A00 AOC specifications; MFA1A00 ordering list; MCP7F00-A breakout specifications; MMA1B00-C100D SR4 specifications; MMA1B00-E100 specifications; MMA1L10-CR LR4 specifications; NVIDIA SN2000 switch manual: cable installation; NVIDIA LinkX Ethernet AOCs.

Parts we stock

Parts in this post

NVIDIA now lists the MCP1600-C, MFA1A00 and MCP7F00 series under Products No Longer For Sale. If your installed base runs on them, matching spares come from recovered stock. Every unit we ship is rebuilt and tested before it leaves. For cables, we inspect connectors and latches, check the label, part number and length, inspect the jacket, and run an electrical test where a test setup for the cable type is available. See how we build and the full interconnect range.

Cabling a Spectrum switch? Our SN2100 cable guide covers DAC, breakout and AOC options for that switch.

FAQ

What is the maximum length of a QSFP28 100G passive DAC?

MCP1600 passive DACs are offered up to 5 m in both the C (100GbE) and E (InfiniBand EDR) versions. For Ethernet, cables up to 2 m are specified as CA-25G-N without FEC, and 3 m to 5 m cables as CA-25G-L with RS-FEC. Beyond 5 m, use an AOC such as the MFA1A00.

Can an MFA1A00-E InfiniBand EDR AOC be used in a 100GbE Ethernet network?

NVIDIA states that its EDR AOCs and transceivers work in NVIDIA end-to-end Ethernet applications. The reverse is not guaranteed: the MMA1B00-C100D Ethernet transceiver is generally not supported in InfiniBand applications. For DACs, match the letter: MCP1600-C for Ethernet, MCP1600-E for InfiniBand EDR.

How much power does a 100G AOC use compared with a DAC?

An MFA1A00 AOC draws 2.2 W typical at each end with retiming, or 1.5 W typical without retiming. An MCP1600-C passive DAC draws 0.1 W maximum. Over many links, copper saves power wherever the run fits within 5 m.

Does the MCP7F00 breakout cable work in any QSFP28 switch port?

Only in a port that supports split mode and is configured for it. On the SN2100, every QSFP28 port can split into 4xSFP28 with no blocking. On the SN2700 and SN2410, only the top ports split into four, and the port below is blocked. The MCP7F00-A carries 100GbE to 4x25GbE at lengths up to 5 m.

When should I use MMA1B00 SR4 transceivers instead of an AOC?

Use transceivers when the fiber passes through patch panels or the length may change. The MMA1B00-C100D uses an MPO connector at 850 nm and reaches 100 m on OM4 or 70 m on OM3. Past 100 m, the MMA1L10-CR LR4 module reaches up to 10 km on single-mode fiber.

Not sure which length or letter fits your fabric? Send us the part number or the requirement and we will match it.